Back to news
EquipmentPublished: 14 November 2026Skyluma editorial desk4 min readFrance and the United States

Vector SE: a new reserve pin cover flap. France's federation requires it by year end, UPT calls its bulletin informational

On 19 October the manufacturer UPT published a bulletin about a new flap covering the reserve pin on large Vector SE containers. The French parachuting federation had already made the replacement mandatory in July, with a deadline of 31 December 2026. The documents differ on status, scope and the description of the problem.

A skydiver's harness and legs in freefall against the skyPhoto
Skyluma

In brief

  • UPT will supply a new reserve pin cover flap for Vector SE containers from size V3SE 364 up, made from 1 May 2013 to 16 July 2026.
  • The manufacturer calls its bulletin informational and says the flap should be fitted at the next scheduled reserve inspection and repack.
  • France's FFP made the replacement mandatory at its centres by 31 December 2026, after ground tests showed delayed reserve container openings.

United Parachute Technologies (UPT), the US maker of the Vector and Sigma containers, published a product information bulletin on 19 October 2026 covering Vector SE containers in size V3SE 364 and larger, manufactured between 1 May 2013 and 16 July 2026. It will supply them with a modified flap covering the reserve closing pin, which it describes as a proactive product improvement.

What UPT says

According to the bulletin, the new flap should be fitted by a qualified rigger at the next scheduled reserve inspection and repack, following UPT's instructions. The bulletin requires no action unless an unusual hesitation in the reserve container opening has been observed on a rig. In that case the rig should be taken out of use and UPT contacted.

UPT says the French federation reported a hesitation during a manual reserve pilot chute extraction carried out as a routine test at the annual repack. The manufacturer reviewed packing procedures and closing loop tolerances, including loops outside tolerance, but could not reproduce a lock-up or a hesitation on a rig maintained to its instructions.

What the French federation requires

The Fédération Française de Parachutisme (FFP) acted earlier. Safety circular CS 211 of 5 May 2026 stopped jumping on these containers until a filmed ground extraction test of the reserve had been done. Circular CS 212 of 6 July 2026 says that analysis of the videos from those tests found several cases of delayed opening or non-opening of the reserve container on containers larger than V3SE 364 with a silicone closing loop of nominal length. According to the circular, UPT's analysis found that the current flap can catch on its own fold, and the FFP made the manufacturer's recommendation, a shorter rounded flap with a modified fold, mandatory.

  • first, a filmed ground extraction test of the reserve by a qualified packer; any delay or lock-up must be reported to the federation
  • then a qualified rigger replaces the flap with the kit supplied by UPT, following the manufacturer's instruction INSTRUCT-065
  • the work is recorded in the rig's documents and the container number reported to UPT
  • deadline: 31 December 2026

Where the documents part ways

First, status: for the FFP the replacement is mandatory with a deadline; for UPT it is an informational bulletin, with the flap fitted at the next scheduled repack. Second, scope: UPT covers V3SE 364 and larger made up to 16 July 2026, while the FFP covers sizes larger than V3SE 364 with no end date. Third, the problem: UPT speaks of a hesitation it could not reproduce, the FFP of several recorded cases of delayed opening or non-opening of the container in ground tests.

The FFP circulars apply at French centres. They are neither Polish rules nor a manufacturer's bulletin. An owner of a Vector SE in size V3SE 364 or larger who jumps in Poland, or is heading to France, should establish with a qualified rigger whether the rig is covered and when to replace the flap.